青年中文青年中文

secondary arc的意思

secondary arc中文翻譯:

潛供電弧,二次電弧

相似詞語短語

secondary───n.副手;代理人;adj.第二的;中等的;次要的;中級的

arc───n.弧(度);弧光(全稱electricarc);弧形物;天穹;vt.形成電弧;走弧線;n.(Arc)人名;(法)阿爾克;adj.圓弧的;反三角函數的

arc flash───電弧閃光

secondary consumer───次級消費者

secondary education───中等教育

jerboa arc───跳鼠弧

secondary color───次生色;n.合成色,間色;二次色

fordo arc───福爾多弧

refract arc───折射弧

雙語使用場景

The key factors influencing the secondary arc current and the recovery voltage were researched.───了影響潛供電流和恢復電壓的關鍵因素。

mechanism of secondary arc extinction by high speed grounding switches (HSGS) is analyzed.───快速接地開關(HSGS)熄滅潛供電弧的機理進行了分析。

The Test Research on Secondary Arc of the Line with Compensation in the Power System .───電力系統潛供電弧有補償情況的試驗研究。

The key factors influencing the secondary arc current and the recovery voltage were researched.───研究了影響潛供電流和恢復電壓的關鍵因素。

The mechanism of secondary arc extinction by high speed grounding switches (HSGS) is analyzed.───對快速接地開關(HSGS)熄滅潛供電弧的機理進行了分析。

however, from the viewpoint of reducing secondary-arc currents and induced voltage, the transposing mode 1 is more suitable.───從減少潛供電流和感應電壓的角度來看,采用換位方式1更佳。

Twice-Modal Transformation Method for Calculating Secondary Arc Current and Recovery Voltage at Double-Circuit Transmission Lines───計算同桿雙回輸電線路潛供電流與恢復電壓的二次模方法

Secondary Arc Parameters Characteristics of Long-distance Series Compensated Transmission Lines───串聯補償的遠距離輸電線路潛供電弧參數特性

Effects of Grounding Resistance on Secondary Arc Current in Extra-High-Voltage Transmission Lines───故障點接地電阻對超高壓輸電線路潛供電流的影響

英語使用場景

The mechanism causing secondary arc current and recovery voltage of two compact circuits with the same array of phase in one pylon window is introduced.

This paper presents the theory of generating secondary arc current in ultra - high - voltage ( UHV ) power transmission system.

The key factors influencing the secondary arc current and the recovery voltage were researched.

The mathematic representations of recovery voltage and secondary arc current can be obtained based on circuit principle, and the values can also be obtained by using MATLAB.

Based on SIMULINK the whole circuit has been simulated, thus, the waveshapes of recovery voltage and secondary arc current are obtained.

A new method for calculating secondary arc current and recovery voltage on double-circuit transmission lines by twice-model transformation was proposed.

The amplitudes of secondary arc current and recovery voltage are two decisive factors to extinguish secondary arc.

The mechanism of secondary arc extinction by high speed grounding switches (HSGS) is analyzed.

High Speed Grounding Switches ( HSGS ) is one of the most effective methods of secondary arc extinction.